Detectors

HPM-100-40 data sheet, application note, prices,

  • High Speed Hybrid Detector for TCSPC

  • Instrument response function 120 ps FWHM

  • No afterpulsing

  • GaAsP cathode

  • Overload protection

  • Direct interfacing to all bh TCSPC systems

  • 3 mm cathode diameter

  • Power supply and control via DCC-100 module

  • Clean response, no tails or secondary peaks
     

 

HPM-100-50

data sheet, application note, prices,

  • High Speed Hybrid Detector for TCSPC

  • Instrument response function 125 ps FWHM

  • No afterpulsing

  • GaAs cathode

  • Sensitivity up to 900 nm

  • Overload protection

  • Direct interfacing to all bh TCSPC systems

  • 3 mm cathode diameter

  • Power supply and control via DCC-100 module

  • Clean response, no tails or secondary peaks
     

 

id100 from Id Quantique

 

data sheet, evaluation note prices

  • Ultra-Low Noise versions available: 20µm < 1cps, 50µm < 20cps

  • Time resolution 40 ps

  • Low dark count rate ( typically 50 Hz )

  • Low dead time ( 45 ns )

  • Peak photon detection @ 500 nm

  • Active area diameter of 20 µm or 50µm

  • Standard 50 Ohm output ( BNC )

  • Not damaged by strong illumination

  • C-MOUNT adapter
     

Applications: Time-Correlated Single Photon Counting, Single molecule detection, Fluorescence correlation spectroscopy
H7422 from Hamamatsu data sheet

  • Time resolution 200 ps

  • High QE (50% peak)

  • Low Noise (typical 100 cps )

  • Internal cooling

  • Useful photocathode 5 mm

  • Standard 50 Ohm output ( BNC )

  • Operated via bh DCC-100 detector controller
     

Applications: Time-Correlated Single Photon Counting, Single molecule detection, Fluorescence correlation spectroscopy

 

R3809 from Hamamatsu data sheet

  • Time resolution 25 ps IRF with
    bh TCSPC modules

  • Low Noise

  • Compact profile

  • Useful photocathode 11 mm

  • Standard 50 Ohm output ( SMA )
     

Applications: Time-Correlated Single Photon Counting, Single molecule detection, Fluorescence correlation spectroscopy

 

PMC-100

data sheet, prices

  • Cooling Control and Overload Shutdown via bh DCC-100 module

  • Excellent TCSPC Instrument Response: < 200 ps FWHM

  • Internal GHz Preamplifier: High Output Amplitude

  • Internal GHz Preamplifier

  • Overload Indicator and TTL / CMOS Overload Output

  • +12V Supply - Internal High Voltage Generator!

  • Excellent Noise Immunity

  • Standard C Mount AdapterExcellent Photon Counting Performance

  • Direct Interfacing to all bh Photon Counting Devices

  • Operated via bh DCC-100 detector controller
     

Applications: Time-Correlated, Steady State and Gated Photon Counting, Non-descanned Detector for TCSPC Imaging
 

SPAD-8

data sheet

  • 8-channel SPAD detector module

  • bh multi-dimensional TCSPC technique

  • Interfaces directly to all bh TCSPC systems

  • Simultaneous measurement in all 8 channels

  • 1 x 8 arrangement of detector channels

  • Instrument response width 70 ps FWHM

  • Max. count rate >5 MHz

  • Thermo-electrically cooled

  • Power supply anc control via bh DCC-100 detector controller card
     


 
 

 

PML-16-C data sheet, operating manual, prices

  • Operation via bh DCC-100 detector controller

  • High voltage power supply included

  • 16 Channel TCSPC with bh SPC Modules

  • Simultaneous Measurement in all 16 channels

  • 1 by 16 Arrangement of Detector Channels

  • Time Resolution 200 ps FWHM

  • Spectral Ranges:  300-650 nm, 300-820 nm

  • Count Rate up to  4 MHz

  • Part of the bh Multi-spectral FLIM Detection system
     

Applications: Time-Correlated, Steady State and Gated Photon Counting, Non-descanned Detector for TCSPC Imaging
 

 
APM-400 data sheet, prices

  • Avalanche Photodiode Module   

  • Active Areas from 0.03 mm² to 7 mm²

  • 150 ps Pulse Rise Time / 320 ps FWHM

  • Internal Temperature Compensation

  • Spectral Range from 330 nm to 1100 nm

  • Single +12V supply
     


PHD-400 data sheet, prices

  • Photodiode Module   

  • Pulse Response Width 400 ps

  • Pulse Rise Time <200 ps

  • Spectral Range 330-1050 nm

  • Current Indicator

  • +5V or +12 V Supply


PDM-400 data sheet, prices

  • Photodiode Module   

  • Pulse Response Width 400 ps

  • Pulse Rise Time <200 ps

  • Spectral Range 330-1050 nm

  • +5V or +12 V Supply

     


PDI-400 data sheet, prices

  • Integrating Photodiode Module

  • Pulse Energy Measurement

  • Low Noise, High Dynamic Range

  • Sensitivity in the fJ Range

  • Active Area from 0.25 to 7.5 mm²

  • Power Supply ±5 to ±15 V
     



PMH-100 data sheet, prices


 

  • Excellent Photon Counting Performance

  • Time Resolution < 200 ps FWHM

  • Spectral Ranges: 300-650 nm, 300-820 nm, 185-820 nm

  • Count Rate > 10 MHz

  • Internal GHz Preamplifier

  • Overload Indicator LED

  • +12V Supply - No HV required!

  • Small Size, Low Cost
     

   

 

 

      

 

 

 


 

 