***** Enter A New World of Imaging *****
Spectral lifetime detection
|
MW-FLIM
Multi-Wavelength FLIM Detectors |
|
 |
Parallel detection of 16 FLIM
images in 16 wavelength intervals
|
 |
Based on BH´s
multi-dimensional
TCSPC technique
|
 |
No wavelength scanning
|
 |
No wavelength scanning artifacts
|
 |
No rejection of photons |
 |
Near-ideal
counting efficiency |
 |
Minimum
sample exposure |
 |
Short
acquisition times |
 |
Compatible
with existing bh FLIM systems |
 |
Controlled
via bh DCC-100 detector controller |
 |
Internal
generator for PMT operating voltage |
 |
Available
for confocal microscope and multiphoton microscopes with non-descanned
detection |
 |
Target
applications: Autofluorescence imaging of cells and tissue,
combination of FLIM-FRET and spectral FRET Techniques |
|
The bh MW FLIM is the first
non-descanned simultaneous multi-spectral detection system.
And it is not only
multi-spectral, it is even FLIM.
|
|
|

|
Data sheet,
Handbook
|
MW-FLIM
for Multiphoton Non-Descanned Detection Systems |
 |
Wide-area non-descanned (direct)
detection
|
 |
High efficiency for
multiphoton imaging of deep tissue layers
|
 |
Light transfer by fibre
bundle
|
 |
Adapters for NDD switch box
of Zeiss LSM 510
|
 |
Adapters for Leica SP2 and
SP5 RLD ports
|
 |
Compatible with bh SPC-730,
SPC-830 and SPC-150 FLIM systems
|
 |
Protected by shutter and
overload shutdown
|
|
 |
|
Data sheet,
Handbook, Handbook
Zeiss FLIM
MW FLIM for Confocal Detection Systems
 |
Detection via confocal ports of laser scanning microsco pe
|
 |
Coupling via fibre outputs: Zeiss LSM 510,
Olympus FV1000, Nikon C1
|
 |
Coupling by fibre bundle: bh DCS-120, Leica SP2
and SP5 D FLIM
|
 |
Compatible with bh SPC-730, SPC-830 and SPC-150
FLIM systems
|
 |
Protected by overload shutdown
|

Data sheet,
Handbook,
Handbook DCS-120
|
PML-Spec |
|
 |
 |
Simultaneous recording of
time- and spectral information
|
 |
16 parallel signal
channels
|
 |
Input for optical fibres (
SMA-905 )
|
 |
Connects directly to SPC-630,
SPC-730, SPC-830 and Simple-Tau
|
|
Data sheet
|
PML-16-C |
|
 |
 |
High voltage power supply
included
|
 |
16 Channel TCSPC with
bh SPC Modules
|
 |
Simultaneous Measurement in all 16 channels
|
 |
1 by 16 Arrangement of Detector Channels
|
 |
Time Resolution 200 ps FWHM
|
 |
Spectral Ranges: 300-650 nm, 300-820 nm
|
 |
Count Rate up to 4
MHz
|
|
Data
sheet,
Handbook
|
|

|
|
© 1993-2010
Becker & Hickl GmbH
Nahmitzer Damm 30
12277 Berlin |
Geschäftsführer: Dr. Wolfgang Becker, Helmut Hickl
Amtsgericht Berlin-Charlottenburg HRB 50729
Steuernummer: 29 410 05494
USt-IDNr: 164939770 |
email
info@becker-hickl.com
fon +49 (30) 787 56 32
fax +49 (30) 787 57 34 |
|
|